Thermo Scientific™ Choice™ Nylon Syringe Filters are a good option for most general laboratory filtration applications and filtration of most HPLC samples. These sryinge filters provide cleaner sample extracts by removing interfering materials and fine particles down to the rated pore size.
National Target All-Plastic Disposable Luer-Slip Syringes, 1mL capacity Catalog number: S7510-1 Pack of 100 Add to cart Titan3™ Nylon Syringe Filter, 30mm, 0.2µm, 100 Pack, PreFilter 42225-NN Pack of 100 Add to cart Titan3™ PTFE (Hydrophobic) Syringe Filters, 0.45µm, 4mm 44504-NP Add to cart
Offering low extractable membranes and housing, Thermo Scientific™ Titan3™ Nylon Syringe Filters are HPLC performance tested, and color-coded to easily select the correct membrane and pore size. An enhanced Luer Lock inlet prevents leakage. A 1mm boro-silicate glass pre-filter is provided with most 30mm devices, pressure rated to 120psi.
Nylon Syringe Filter Pharmassure on Sale Kenya Nylon Syringe Filter at Thomas Scientific Syringe Filter, Nylon, 0.22µm, 30mm Diameter Denville Denville Scientific Syringe Filters are constructed so that the sample must pass through the membrane, not leak around it.
Nylon Syringe Filters, 0.45 um, 33mm, Luer-Lok/Luer Slip, Nonsterile, 100 per pack, SF16003 Regular Price$127.34Price$110.73As low as$99.66 Add to Cart Add to Wish List Nylon Syringe Filters, 5 um, 25mm, Double Luer Lock, PP Housing, Nonsterile, 100 per pack, SPEC18120
Nylon Syringe Filter Pharmassure OEM Kenya Syringe Filters Manufacturer and Supplier | Nylon Syringe Filters Features. • 13 and 25 mm diameter syringe filters. • 13 mm devices for samples up to 10 ml and 25 mm devices for samples greater than 10 ml (however, the volume of sample that can be filtered through each filter depends on the
Acrodisc® Syringe Filters Optimized for Scale Up, 25 mm - 0.2 µm, Ultipor membrane, sterile (50/pkg) Product ID. 4906.
Choice Nylon Syringe Filter Specifications. Membrane: HPLC certified nylon. Maximum operating temperature: 100 °C. Housing: Medical grade, virgin polypropylene. Autoclave: Sterilize by dry heat at 121 °C for 15 minutes. Choice Nylon Syringe Filter Applications. HPLC and organic-solvent sample preparation and clean-up. Dissolution sample analysis.
PharmAssure Syringe Filters with Supor Membrane Single use Supor polyethersulfone membrane Maximum operating pressure: 75 psi (5.2 bar) Non-pyrogenic Sterile Minimal retention volumes: 50 µL for the 25 mm and < 100 µL for the 32 mm filter PharmAssure 25 mm Vent Filters 0.2 µm hydrophobic vent membrane Maximum operating pressure: 15 psi
EZFlow 13mm, 25mm, and 33mm Syringe Filters are used for prefiltration, clarification, sterilization, or fine particulate removal. These syringe filters are available in a variety of filter membrane materials in both 0.2um and 0.45um pore sizes. The filter membranes are reinforced with polypropylene housing, with a female Luer-lok inlet and a
Pall supplies a comprehensive family of syringe filters offering a full range of sizes, volumes, and flow rates. Sterile syringe filters are typically used in life science applications to sterilize solutions or for clarification. Non-sterile syringe filters are used across a range of filtration and sample preparation applications.
PharmAssure Vent Filters, individually packaged Part No. Description Packaging HP2002 0.2 µm, 25 mm vent filter, clear/clear 50/box PharmAssure Dispensing Pins, individually packaged Part No. Description Packaging HP2402 0.2 µm, modified acrylic 50/box 7/11, 2k, GN11.4804 11.4804 United States 25 Harbor PPark Drive Port Washington, NY 11050
Nylon Syringe Filters Sterlitech Nylon filter devices are designed for sterilization and clarification of aqueous and solvent samples in a wide array of analytical and research applications. They are primarily used to filter small aqueous and organic samples with low hold-up volume in order to inject them directly into the HPLC sample loop systems. See full list on sterlitech.com
Nylon syringe filters can be used for both aqueous and solvent-based sample filtration applications and show excellent chemical compatibility with esters, bases and alcohols. However, it should be noted that nylon syringe filters are not recommended for sample fluids which are strongly acidic. 25 mm Standard Acrodisc Syringe Filters Type