Home » News » 25mm Syringe Filter » 33mm 0.45μm Cellulose Acetate Syringe Filter for Sample Preparation OEM

33mm 0.45μm Cellulose Acetate Syringe Filter for Sample Preparation OEM

Cellulose Acetate Syringe Filters – Syringe Filters | Sterlitech Sterlitech cellulose acetate syringe filters are hydrophilic membrane disc filters that are ideal for maximum sample recovery....


Description

Cellulose Acetate Syringe Filters - Syringe Filters | Sterlitech

Sterlitech cellulose acetate syringe filters are hydrophilic membrane disc filters that are ideal for maximum sample recovery. These cellulose acetate membrane filters and cellulose acetate syringes are available as sterile or non-sterile and with or without a glass fiber pre-filter.

Regenerated Cellulose Membrane, RC Membrane - Membrane Solutions

Regenerated Cellulose (RC) membranes are excellently suited for their major application, particle removal from solvents. Regenerated cellulose membranes also feature low non-specific adsorption. The 0.45 μm, 50 mm diameter pore size filter, for example, is standardly used to ultraclean and de-gas solvents and mobile phases for HPLC.

Cellulose Acetate Syringe Filters, Sterile, Abluo, 5.0 Micron

Cellulose Acetate Syringe Filters, Sterile, Abluo, 5.0 Micron, 25mm, 50/pk. For maximum sample recovery, choose Sterlitech’s sterile cellulose acetate syringe filters. Low-binding and hydrophilic, these sterile cellulose acetate syringe filters are available with or without a glass fiber pre-filter and boast both strength and a uniform pore

Target2™ Regenerated Cellulose Membrane, 4mm, 0.45μm (F2504-7)

Adding a syringe filtration step prior to injection not only helps to ensure more consistent and reliable results; it also helps protect delicate instruments and prolongs column life.Available in sizes and membrane types to meet any application need, Thermo Scientific™ Target2™ Syringe Filters provide cleaner sample extracts by removing interfering materials and fine particles.

Target2™ Cellulose Acetate Syringe Filters

Target Polypropylene Syringe Filter Housings Meet The Requirements of 21 CFR 177.1520. Target2 Cellulose Acetate Syringe Filter 0.2 µm, 17 mm, 100 Pk. Target2 Syringe Filters are an ideal choice for general purpose laboratory use. Robust and reliable, they deliver excellent performance at an attractive price.

Millex® Syringe Filter Units, Sterile, 33mm - Sterile Syringe

Millex-GP filters are recommended for sterile filtering protein solutions, tissue culture media, buffers and additives. Millex filters with Durapore® (PVDF) membrane are the lowest protein-binding syringe filters available. Use them to filter protein solutions. The 0.2 µm filters are sterilizing grade.

Sartolab® RF Vacuum Filtration Units 180A2----------E, 0.45

Sartolab ® RF with cellulose acetate (CA) is designed for particle and cell removal. Type A2 is a bottle top unit including receiver flask (RF) with a pore size of 0.45 µm and a volume of 500 ml. It can be used for sterile clarification of aqueous solutions. Version E contains 12 units which are individually packed and sterilized.

Target2™ Cellulose Acetate Membrane, 17mm, 0.45μm (F2513-15)

Adding a syringe filtration step prior to injection not only helps to ensure more consistent and reliable results; it also helps protect delicate instruments and prolongs column life.Available in sizes and membrane types to meet any application need, Thermo Scientific™ Target2™ Syringe Filters provide cleaner sample extracts by removing interfering materials and fine particles down to the

Cellulose Acetate Syringe Filters, Advantec, Sterile, 0.20

Cellulose Acetate Syringe Filter Specifications (Sterile) Filter. 25 mm. Cellulose Acetate. Yes. Borosilicate Glass Prefilter. Sterile (*Gamma Radiation) Yes*. Autoclavable.

MF-Millipore™ Membrane Filter, 0.45 µm pore size | HAWP04700

HAWP04700. Trade Name. MF-Millipore. Description. MF-Millipore™ Membrane Filter, 0.45 µm pore size. Background Information. Biologically inert mixtures of cellulose acetate and cellulose nitrate have made MF-Millipore™ membrane filters one of the most widely used membranes in analytical and research applications.

Whatman® GD/X syringe filters glass microfiber membran, pore

The prefilter will retain fine particles down to 0.7 μm, allowing difficult sample filtration with less hand force. The volume of the sample filtered is 3-7 times greater than an unprotected membrane. PP housing. Syringe filters can be autoclaved. Membranes: Cellulose Acetate: for biological solutions, high-loading capacity, and low-protein

CA (Cellulose Acetate) | Johnson Test Papers

Cellulose acetate syringe filters exhibit very low protein binding, so they are suitable for protein recovery applications. The 0.22μm pore size CA membrane is especially suited for sterilising aqueous solution, buffers, sera and media.

PVDF-D (Polyvinylidene Fluoride) | Johnson Test Papers

PVDF-D (Polyvinylidene fluoride) syringe filters have very low protein binding and high tensile strength. They are employed for filtering non aggressive aqueous and mild organic solutions, or where increased protein retrieval is critical making them appropriate for biomedical filtration, sterilisation filtration, and HPLC sample preparation.

Cellulose Acetate Syringe Filters - Samples Available - Ships

Tisch Scientific Cellulose Acetate (CA) Syringe Filter, 3.0 µm, 20 mm, Threaded Double Luer Lock, Nonsterile, 100 Pack, SPEC18180. Price $98.00 As low as $74.97. Add to Cart. Add to Wish List. Cellulose Acetate CA Syringe Filters, 0.22 um, 13mm, Luer-Lok/Luer Slip, Nonsterile, 100 per pack, SF14485.

Sterile Syringe Filter,SteriBio Syringe Filters – Membrane

Especially 0.22um pore size CA Sterile Syringe Filter excellently suited for sterilization aqueous solutions, buffers, sera and media. Low protein binding to minimize sample loss. PES (polyethersulphone)resistant to a wide range of solvents and offers low binding to proteins and nucleic acid. PES is also recommended for ion chromatography.

Inquiry
Name:
Email:
Tel:
Country:
Content: